INSTALLATION
Installation with gate motors:
• Installation of the gate driver may be performed only by certied
professionals.
• The motor must be equipped with the appropriate limit switches.
• It is recommended to connect a NC (normally closed) contact of
an IR barrier to S2 terminal. Opening the contact will stop the gate.
• In addition, it is recommended to connect an emergency stop
button to the motors neutral (N) wire. In emergency, pushing the
emergency stop button will cut the power and stop the gate.
Wiring diagram - gate motors
1. Switch o the mains voltage (disable the fuse).
2. Open the installation box.
3. Connect with the following the diagram:
4. Verify if the device is connected correctly.
5. Arrange the device and its antenna in the installation box.
6. Close the installation box.
7. Switch on the mains voltage.