7
INSTALLATION
Installation with gate motors:
Installation of the gate driver may be performed only by certied
professionals.
The motor must be equipped with the appropriate limit switches.
It is recommended to connect a NC (normally closed) contact of
an IR barrier to S2 terminal. Opening the contact will stop the gate.
In addition, it is recommended to connect an emergency stop
button to the motors neutral (N) wire. In emergency, pushing the
emergency stop button will cut the power and stop the gate.
L
N
M
N
safety switch
NC
sensor
NC
Roller
Shutter 3
B
limit
switches
L NS1 S2 Q2 Q1
PE
Wiring diagram - gate motors
1. Switch o the mains voltage (disable the fuse).
2. Open the installation box.
3. Connect with the following the diagram:
4. Verify if the device is connected correctly.
5. Arrange the device and its antenna in the installation box.
6. Close the installation box.
7. Switch on the mains voltage.

Other manuals for FIBARO ROLLER SHUTTER 3