图 3- 13 Reset Timing Control
RESET can be conducted only when system crash or no response occurs to L831-EAU module;
if the problem cannot be resolved after RESET, it’s recommended to pull down
FULL_CARD_POWER_OFF# for at least 500ms, and then pull it up to complete module reset.
The L831-EAU module supports USB 2.0(High-Speed 480 Mbits/s). For the USB timing and electrical
specification of L831-EAU module, please refer to “Universal Serial Bus Specification 2.0”。
The USB of L831-EAU module can map one MBIM interface and one GNSS Sensor in Win10 system
GNSS Sensor used for processing GNSS positioning
MBIM interface used for initiating data services
3.4.1 USB Interface Definition