8 - Maintenance
- Message on di-
splay
- Signal
Name of Derating and Cause Solution
- LIMxxx% CODE:05
Power limitation due to excess temperature:
The message indicates that a power limitation is active since an
excess temperature condition has been recorded inside the inver
-
ter (This parameter depends also on the power which the inverter
must provide since the measurement of temperatures is taken
internally and is inuenced by the heat dissipated by the compo
-
nents of the inverter itself).
LIM xxx% = Power reduction percentage
Examples:
LIM 100% = no power limitation
LIM 50% = limitation to 50% of the output nominal power
• Check that the inverter is not exposed to direct
sunlight. Wait for the temperatures to which the in
-
verter is exposed to return to the operating range
and for the inverter to cool down.
- If the problem (once the ambient temperature has
returned within the range) persists, contact custo
-
mer assistance.
- LIMxxx% CODE:06
Power limitation for input over-voltage:
The message indicates that a power limitation is active since an
input overvoltage (AC) has been recorded.
LIM xxx% = Power reduction percentage
Examples:
LIM 100% = no power limitation
LIM 50% = limitation to 50% of the output nominal power
• It is necessary to measure the input voltage inside
the inverter with a voltmeter.
- If it is higher than the maximum voltage of the ope
-
rating range, the alarm is genuine and it is necessa-
ry to check the conguration of the PV generator. If
the voltage has also exceeded the maximum input
threshold the inverter could be damaged.
- If it is lower than the maximum voltage of the ope
-
rating range, the alarm is caused by an internal
malfunction and it is necessary to contact customer
assistance.