Attachments
Port and network services used by the inverter
IP Network Services
Any network connected to the inverter must allow trafc to pass on the
following ports. Network rewall rules (if present) must allow responses
to the inverter over existing TCP connections.
Direction Service/Port Protocol Description
Out ssh/22 Tcp
For remote debugging by FIMER service personnel, the
inverter utilizes encrypted SSH Remote Login Protocol. To
allow service personnel remote access to the inverter, this
port has to be opened in any rewall and forwarded to the
inverter. (preferred)
Out domain/53 Tcp/udp
The inverter must be able to resolve domain names, to en
-
sure scalability and dynamic changes on the Internet (DNS).
(required)
Out https/443 Tc p
As an HTTP client, the inverter uses SSL/TLS protocol con
-
nections to Aurora Vision
®
servers for secure communica-
tion. The inverter uses this port for all services, including
data transmission, rmware upgrade, conguration mana-
gement, and remote command transmission. (required)
Out
dhcp/67,
dhcp/68
Udp
If DHCP service is not available, static network information
must be assigned to the inverter (preferred)
Out ntp/123 Udp
The inverter uses this port for network time services (NTP).
(preferred)