FUNCTIONING
16
4
4.4 SHIELDING GAS SUPPLY
Injuries danger caused by overthrow of the gas protection cylinders!
Gas protection cylinders can overturn in case of inadequate xing and seriously injure people!
Assure the protection gas cylinders by the available protection elements provided on trolleys
Protection gas cylinders must join rmly to the matching circumference!
On the protection gas cylinder valve must not be any xing element!
4.5 SHIELDING GAS QUANTITY REGULATION
Wrong use of protection gas cylinders
A wrong use of protection gas regulation can cause hard injuries and death.
Follow the gas manufacturer indications and the suggestions for pressured gas!
Install the gas cylinder in the arranged seat and assure it by protection elements!
Avoid overheating of protection gas cylinder
4.6 MIG/MAG WELDING SHIELDING GAS SETTING
WELDING PROCESS RECOMMENDED PROTECTION GAS QUANTITY
MIG WELDING Ø WIRE x 11.0 = l/min
MAG WELDING Ø WIRE x 11.0 = l/min
ALLUMINIUM WELDING Ø WIRE x 13.0 = l/min (100% Argon)
NOTE: Both low and high settings can let air penetrate into welding pool, causing
the making of pores.
Gas quality MUST be adapted to the welding work type.