SECTION 1
INFORMATION AND REQUIREMENTS
1.0 APPLIANCE INFORMATION
Model FHKC**MN2
FHLC**MN2
FHLP**MN2
FHDC**RN3
FHDP**RN3
FHKCEHRN
Gas type G20
Main injectors (2 off) Size 130 (MC) 170 (RC)
Pilot type (MC) Copreci 21100 / 141
Pilot type (RC) ERTA OXYP PG-83-10
Max. gross heat input : 4.5 kW
Min. gross heat input : 3.5 kW
Cold pressure : 20.0 +/- 1.0 mbar
Ignition : Push button piezo (MC models)
1.5V battery generator (SC models)
4.5V battery generator (RC models)
Electrode spark gap 4.5mm nominal
Weight 20kg (all models)
Fire box Dimensions (with standard trim) - for all other models please
consult manufacturer
Width : (with standard trim) 498mm
Height : (with standard trim, no spacer) 600mm
Depth : (overall-without fender) 180mm
Depth : Flush-fit (from mounting face to rear) 180mm
Depth : Flush-fit (mounting face to rear 130mm
with 50mm spacer fitted)
Gas Connection 8mm Compression (Supplied with fire)
This appliance is manufactured by :-
BFM Europe Ltd, Trentham Lakes, Stoke-on-Trent, ST4 4TJ
Appliance Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2009 + A1 : 2013 and the result is 76.6%. The gross calorific value of the
fuel has been used for this efficiency calculation.
The test data from which it has been calculated has been certified by BSI. The
efficiency value may be used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings.