EasyManuals Logo

Flexim FLUXUS ADM 8027 User Manual

Default Icon
160 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #160 background imageLoading...
Page #160 background image
FLUXUS ADM 8027, F801, ADM 8127B E System Design in Accordance with IBExU07ATEX1061
160 UMFLUXUS_F8V4-6-1EN, 2018-10-10
E System Design in Accordance with IBExU07ATEX1061
cables
L-YY(ZG)Y-2x2x0.5-60V-blue:
operating capacitance: max. 90 nF/km
inductance (loop 800 Hz): max. 0.8 mH/km
length: max. 80 m
power supply unit
NG3-12ib
FHF Bergbautechnik
U
0
= 12.15 V
I
0
= 1.27 A
C
ext
= 15 μF (at L
0
= 0 H)
L
ext
= 70 μH (at C
0
= 0 F)
-20 °C T
a
+60 °C
transmitter
FLUXUS ADM 8127B
FLEXIM GmbH
U
i
13.2 V DC
L
i
, C
i
negligible
-20 °C T
a
+50 °C
terminal
+
-
L-
L+
PE
or
L-2YYC(ZG)Y-2x2x0.5:
operating capacitance: max. 55 nF/km
inductance (loop 800 Hz): max. 0.8 mH/km
length: max. 80 m
part contained in system approval IBExU07ATEX1061
frequency output 5…15 Hz
binary output
(not part of this system approval
because completely galvanically isolated)
transducer circuits
not intrinsically
safe
230 V AC
terminal