4 Start-up sequence
At power-on all displays will show the following sequence steps, where
each step is approximately 2 seconds:
• All segments and digits on
• All segments and digits off
• Display indicator type 47-11
• Display program version in the format ‘Px M.nn’ where M is major
and nn is minor revision, x- designates custom factory default
settings.
• Display of OIML mode (if activated)
• Display of alibi status (when applicable and enabled)
• Display of maximum capacity plus one scale interval (d), in the
case of multiple interval/range configuration, each interval and
corresponding scale interval is displayed
The indicator then prepares for normal operation:
• Checks if power on zero is enabled, if enabled weight display will
flash and no weighing functions are available until power-on zero
criteria’s are meet or the operator chooses to abort by pressing
the <Abort>/<Back> button