EasyManua.ls Logo

FLIR DM166 - Page 32

FLIR DM166
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FLIR DM166 USER MANUAL Document Identifier: DM166-en-US_AA
32
Audible Continuity Tester
Continuity Threshold: Between 30 and 480
Continuity ON Response Time: <15ms
Capacitance
RANGE and RESOLUTION
Accuracy
20.00nF, 200.0nF
1.5% + 8d
2000nF, 20.00F, 200.0F
1.5% + 2d
2000F
2.0% + 2d
10.00mF
5.0% + 10d
Accuracies stated for film capacitors (or better)
Diode Tester
RANGE and RESOLUTION
Accuracy
3.000V
0.9% + 3d
Test Current: 0.3mA typical
Open Circuit Voltage: < 3.2VDC typical
DC Current
RANGE and RESOLUTION
Accuracy
Burden Voltage
600.0A
1)
, 6000A
1)
1.0% + 3d
0.1mV/A
60.00mA
1)
, 600.0mA
1) 2)
0.7% + 3d
1.9mV/mA
6.000A
3) 4)
, 10.00A
3) 4) 5)
0.04V/A
1) A/mA DC accuracy is affected by extreme internal meter temperatures. For rated accuracies, allow linear
proportional cool down intervals from 6 to 20 minutes after measuring currents from 3 to 10A continuously via
A-input.
2) <400mA continuous; >400mA for <20 minutes ON per >5 minutes OFF
3) 10A continuous up to ambient 95°F (35°C); <15 minutes on per >5 minutes off @ 95~122°F (35°C ~ 50°C)
4) >10A to 20A for <30 seconds ON per >5 minutes OFF

Table of Contents