Handling the camera13
Note
Do not touch the lens surface when you adjust the infrared camera focus manually. If this happens,
clean the lens according to the instructions in 27.2 Infrared lens, page 260.
The focus ring can be rotated infinitely, but only a certain amount of rotation is needed when
focusing.
13.7 Autofocusing the infrared camera
13.7.1 Figure
13.7.2 Procedure
Follow this procedure:
1. To autofocus the camera when continuos autofocus is disabled, push the Autofocus/
Save button half-way down.
13.8 Continuous autofocus
13.8.1 General
The camera can be set up to perform continuous autofocusing. In this mode, the digital
camera is used, meaning that continuous autofocus will not work in darkness.
13.8.2 Procedure
Follow this procedure:
1. Push the joystick to display the menu system.
2. Use the joystick to go to
(Settings).
3. Push the joystick to display the Settings menu.
4. Select Device settings and push the joystick.
5. Select Set up camera and push the joystick.
6. Select Continuous autofocus. If the check box is unchecked, push the joystick to ena-
ble continuous autofocus.
7. Aim the camera toward the object of interest. The camera will now continuously
autofocus.
#T559880; r.15724/15724; en-US
26

Table of Contents

Other manuals for FLIR T6 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR T6 series and is the answer not in the manual?

FLIR T6 series Specifications

General IconGeneral
BrandFLIR
ModelT6 series
CategoryThermal cameras
LanguageEnglish

Related product manuals