Maintenance of the Machine
212601 14/03/2023
59
Maintenance interval Assembly
group
Maintenance activities
yearly
six-monthly
quarterly
monthly
weekly
daily
in case of fail-
ure
Danger
Before starting any maintenance or cleaning work, you must
shut down the machine (
(see section 7 Shutting down the machine).
Machine
in general
Free the machine from swarf. Use a hand brush.
Free machine and area around the machine from cooling lubricants.
Check drilling table for wear. Lightly oil with spray oil.
Clean the pillar. Lightly oil with spray oil.
Clean toothed rack. Grease with machine
Move the quill to the lowest position, clean it and lightly oil it.
Lubricate the teeth of the quill.
Clean the control panel.
The function of all lamps of the control panel and the drill lights must be
checked.
Check function of emergency stop button.
Check function of drill guard.
Observe instructions of
the manufacturer
Check wear and function of drill chuck, replace if necessary.
Observe instructions of
the manufacturer
Check function of the inserted workpiece holders (vise, clamping jaws, ...),
replace if necessary.
Observe instructions of
the manufacturer
Check cutters regularly for wear, replace if necessary.
All connection screws must be checked for tightness.
Clean the machine from dust and dirt. The parts that are not easy to access
should be carefully cleaned with compressed air; it may be sufficient to use
a bellows. (Vacuuming is better, but not always practicable).
Check all warning and information signs for completeness and cleanliness,
clean or replace if necessary.
Drive
Check external condition of drive unit.
Check the condition of the pulleys.
Check condition, tension and fit of ribbed V-belt.
Electricity
Check the presence and secure function of the protective hood.
Check the integrity of the connecting cable and the earthing contact plug.
All connection terminals for the control cables on devices and terminal strips
must also be checked.
Replace control panel.