Usage and service notes
The pressure loading tool is a delicate instrument and
must be handled with care.
Use only approved hydraulic oil in the hand pump.
It is critical that service technicians be trained in the
assembly and disassembly procedures of the intensi
-
fier before they use the pressure loading tool.
Do not use the pressure loading tool for anything
other than the assembly and disassembly of the
intensifier.
It is important to collapse the tool (push the piston
fully into its cylinder) before each use as described in
this section, to prevent accidental separation of the
tool.
Inspect the tool piston stop for damage. Replace if it
is not flat. DO NOT grind to remove damage.
For ease of use and to prevent damage, Flow recom
-
mends that you mount the hand pump permanently
to a rigid cart. When not in use, cover the cart with a
dust cover and store in a clean location.
When storing the pressure hose, do not kink or bend
it.
Always keep dust caps in place on the quick discon-
nect fittings when the tool is not in use.
Once a year, the pressure gauge of the tool should
be calibrated by a qualified laboratory.