Functional specifications
Typeofshift..........................electric
Outputpressure........... 94,000psi(6483 bar)
Intensificationratio.....................31.4:1
Operating principles
The intensifier pump consists of a hydraulic system, a
high-pressure water delivery system, and a control
system. Details of the control, hydraulic oil and high-
pressure water systems can be found in the intensifier
pump manual.
The water is pressurized by using the fluid pressure in
-
tensification principle. Hydraulic oil pressure acting on
the piston results in a force on the plunger, which pres
-
surizes the water in the small chamber. Force equilib
-
rium is achieved when the water pressure equals the
hydraulic oil pressure times the effective area of the pis
-
ton divided by the area of the plunger, assuming no fric-
tion losses. The ratio of the effective piston area to
plunger area is defined as the pressure intensification
ratio.
6 | M-376 © Flow International Corporation
94K HYPERPRESSURE INTENSIFIER