REGULATION INSTRUCTIONS
45
P
ARAMETER
17
M
INIMUM
F
AN
S
PEED
S
ETTING
6. Use buttons ‘+’ o ‘-’ to modify the value of the parameter between:
min = 33 Hz ; max = value of parameter 18
The default value is :
- 55 Hz for Natural Gas;
- 52 Hz for propane.;
7. Press and release button ‘S’ to confirm. The parameter number (17)
will appear in the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
P
ARAMETER
18
M
AXIMUM
F
AN
S
PEED
S
ETTING
6.
Use buttons ‘+’ o ‘-to modify the value of the parameter between:
min = value of parameter 17; max = 202 Hz.
The default value is:
- 164 Hz for Natural Gas;
- 155 Hz for propane.;
7. Press and release button ‘S’ to confirm. The parameter number (18)
will appear in the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
P
ARAMETER
19
M
INIMUM
F
AN
S
PEED
S
ETTING
C
ENTRAL
H
EATING
M
ODE
6. Use buttons ‘+’ o ‘-’ to modify the value of the parameter
between: min = 33 ; max = value of parameter 18.
The default value is:
- 55 Hz for Natural Gas;
- 52 Hz for propane.;
7. Press and release button ‘S’ to confirm. The parameter number (19)
(19) will appear in the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
P
ARAMETER
20
M
AXIMUM
F
AN
S
PEED
S
ETTING
C
ENTRAL
H
EATING
M
ODE
6. Use buttons ‘+’ o ‘-’ to modify the value of the parameter
between: min = value of parameter 17; max = 202 Hz.
The default value is:
- 164 Hz for Natural Gas;
- 155 Hz for propane.;
7. Press and release button ‘S’ to confirm. The parameter number (20)
(20) will appear in the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
S
S
17
55
20
164
19
55
S
S
164
18
S
S
S
S
120 60 Hz
120 60 Hz
120 60 Hz
120 60 Hz
120 60 Hz
120 60 Hz
120 60 Hz
120 60 Hz