EasyManuals Logo

Flowserve HPX User Manual

Flowserve HPX
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
34
The minimum flow of the pumps within the system can now be defined and provisions must be
made in the system to assure the total capacity is not less than this.
Total Minimum Flow of = Minimum Flow of Weakest Pump + (total No.Pumps - 1)
Pumps in System (Strong Pump Flow)
Sample: (see Figure )
1. Assume the minimum flow for a single pump is 27 GPM.
2. Data for the head - capacity curve:
At the rated point:
[EQN "[Strongest pump head = 300 +(300x2) over 100 = 306]]
[EQN "[Weakest pump head = 300 - (300x2) over 100 = 294]]
At Shutoff:
[EQN "[Strongest pump head = 360 + (360 x 5) over 100 = 378]]
[EQN "[Weakest pump head = 360 - (360 x 5) over 100 = 342]]
From head capacity curve:
Minimum weakest pump flow = 27GPM
Minimum strongest pump flow = 65GPM
Total minimum flow of pumps in a typical application with 2 pumps operating in parallel.
Total Minimum Flow of Pumps in System = 27 + (2-1) (65) = 92 GPM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flowserve HPX and is the answer not in the manual?

Flowserve HPX Specifications

General IconGeneral
BrandFlowserve
ModelHPX
CategoryWater Pump
LanguageEnglish

Related product manuals