Models 110, 111 & 112
Users Manual
12
Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %.
The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] )
Maximum voltage between any terminal and earth ground: 600 V
Surge Protection 6 kV peak per IEC 61010-1-95
W Fuse for A input: 11 A, 1000 V FAST Fuse
Display: Digital: 6,000 counts, updates 4/sec
Bar Graph: 33 segments, updates 40/sec
Frequency: 9,999 counts
Capacitance: 9,999 counts
Temperature: Operating: 10 °C to +50 °C
Storage: 30 °C to +60 °C
Temperature Coefficient: 0.1 x (specified accuracy) / °C for < 18 °C or > 28 °C
Electromagnetic Compatibility: Performance 3 V/m is not specified.
Relative Humidity: Noncondensing < 10 °C
0 % to 95 % @ 10 °C to 30 °C
0 % to 75 % @ 30 °C to 40 °C
0 % to 45 % @ 40 °C to 50 °C
Battery Life: Alkaline: 300 hours typical, without backlight
Size, with Holster (H x W x L): 4.6 cm x 9.6 cm x 16.0 cm
Weight: 350 g
Safety Compliances: ANSI/ISA-S82.01-1988, CSA C22.2 No 231 and IEC 61010-1-95 Overvoltage Category III
(CAT III), 600 V
Certifications:
UL (3111),
P, CSA, TÜV,
; (N10140), VDE