Models 110, 111 & 112
Users Manual
4
MIN MAX AVG Recording Mode
The MIN MAX AVG recording mode captures the minimum and
maximum input values, and calculates a running average of all
readings. When a new high or low is detected, the Meter beeps.
Put the Meter in the desired measurement function and range.
Press MIN MAX to enter MIN MAX AVG mode.
m and MAX are displayed and the highest reading
detected since entering MIN MAX AVG is displayed.
Press MIN MAX to step through the low (MIN), average
(AVG), and present readings.
To pause MIN MAX AVG recording without erasing stored
values, press HOLD. h is displayed.
To resume MIN MAX AVG recording, press HOLD again.
To exit and erase stored readings, press MIN MAX for at least
one second or turn the rotary switch.
Display HOLD
WWarning
To avoid electric shock, when Display HOLD is
activated, be aware that the display will not change
when you apply a different voltage.
In the Display HOLD mode, the Meter freezes the display.
Press HOLD to activate Display HOLD. (h is displayed.)
To exit and return to normal operation, press HOLD or turn the
rotary switch.
Backlight (Model 112 Only)
Press S to toggle the backlight on and off. The backlight
automatically turns off after 2 minutes.
To disable the automatic 2-minute backlight timeout, hold down
the S button while turning the Meter on.

Other manuals for Fluke 112

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 112 and is the answer not in the manual?

Fluke 112 Specifications

General IconGeneral
CategoryMultimeter
ContinuityYes
Diode TestYes
DisplayDigital
DC Voltage Ranges400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V
Resistance Ranges400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ
Safety CategoryCAT III 600 V
AC Voltage Accuracy±(1.0% + 3)
Battery Type9 V
DC Voltage Accuracy±(0.5% + 2 counts)
AC Voltage Ranges4.000 V, 40.00 V, 400.0 V, 600 V