12 Multimeter
SPECIFICATIONS
25
Maximum Voltage Between any
Terminal and Earth Ground 600 V rms
Display 3 3/4-digits, 4000 counts, updates 4/sec
Operating Temperature -10 °C to 50 °C
Storage Temperature -30 °C to 60 °C indefinitely (to -40 °C for 100 hrs)
Temperature Coefficient 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)
Relative Humidity 0 % to 90 % (-10 °C to 35 °C)
0 % to 70 % (35 °C to 50 °C)
Battery Type 9 V, NEDA 1604 or IEC 6F22
Battery Life 650 continuous hours with alkaline
450 continuous hours with carbon-zinc
Shock, Vibration 1 meter shock. Per MIL-T-28800D for a Class 3 Instrument
Size (HxWxL) 1.35 in x 2.75 in x 5.55 in
(3.46 cm x 7.05 cm x 14.23 cm)
Weight 10 oz (286 g)
Safety Designed to Protection Class II requirement of UL 3111,
ANSI/ISA-S82, CSA C22.2 No 231, and VDE 0411, and IEC
1010 overvoltage category III.
EMI Regulations Complies with FCC Part 15, Class B, and VDE 0871B.

Other manuals for Fluke 12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 12 and is the answer not in the manual?

Fluke 12 Specifications

General IconGeneral
Continuity BeeperYes
Diode TestYes
Safety RatingCAT III 600 V
Operating Temperature0 °C to 50 °C
Display TypeLCD
Voltage DC600V
Voltage AC600V
DC Current Range10 A
AC Current Range10 A
Resistance Range40 MΩ
Battery Type9V
Dimensions169 mm x 84 mm x 44 mm