Fluke 123/124
Getting Started
12
Scope Menu
SCOPE MENU is used to select A and B
input signal conditions like coupling, and
normal/inverted display.
The function keys F1, F2, and F3 give access
to submenus:
SCOPE OPTIONS ...
SCOPE MODE
NORMAL: the scope mode commonly used.
SINGLE SHOT: can be used to catch single
events.
ROLL MODE: is useful for monitoring lower
frequency waveforms.
WAVEFORM MODE
NORMAL: the mode most commonly used.
SMOOTH: is used to suppress noise.
ENVELOPE: envelope records all values of
live waveforms. On the screen the resultant
envelope is displayed.
PROBES ...
PROBE on A: for selection of the correct
probe type when using non-standard probes.
PROBE on B. Identical to Input A description.
PROBE AC ADJUST. For adjustment of 10:1
voltage probes other than the probe supplied
with Fluke 124. This is necessary for correct
high frequency measurements.
TRIGGER ...
INPUT: selection of the trigger source on
which the Test Tool is triggered. EXTernal
triggering is possible via an optically isolated
trigger probe.
SCREEN UPDATE: FREE RUN gives
automatic screen update even if there are no
triggers. ON TRIG only gives screen update
when valid triggers occur.
AUTO RANGE: selection of Auto Set on
signals >15 Hz (fast response) or >1 Hz
(slower).