1630
Users Manual
14
Specifications
Electrical Specifications
Display.................................................................9999 digit liquid crystal display with
special symbols
Operating Humidity..............................................Less than 85% RH
Storage Temperature ..........................................-20 °C to 60 °C (-4 °F to 140 °F)
Storage Humidity.................................................Less than 75% RH
Reference Temperature ......................................23 °C ± 5 °C (73 °F ±9 °F)
Temperature Coefficient......................................0.1 % X (specified accuracy)/ °C
(< 18 °C or > 28 °C)
Operating Temperature .......................................0 °C to +50 °C (+32 °F to +122 °F)
Protective Type ...................................................IP23 according to
IEC 60529/EN 60529
Category Rating ..................................................300 V CAT III/pollution degree 2 and
600 V CAT II
EMC (Emission) ..................................................IEC 61000-4-1, IEC 61326-1 class B
EMC (Immunity) ..................................................IEC 61000-4-2 8 kV (air) criteria B,
IEC 61000-4-3 V/m perf. Criteria A
Range Selection ..................................................Auto
Overload Indication .............................................OL
Measurement Frequency ....................................3.333 kHz
Power Requirement.............................................9 V alkaline (type IEC 6F22, NEDA
1604)
Power Consumption ............................................ Approx. 40 mA (in Ω function)
Low Battery Indicator...........................................M
Maximum Non-destructive Current......................100 A continuous, 200 A (< 10 sec)
50/60 Hz
Accuracy of Calibration Plate ..............................+/- 0.5%
Data Logging Capacity ........................................116 records
Data Logging Interval ..........................................1 to 255 seconds
General Specification
Conductor Size....................................................35 mm (1.38 in) approximately
Dimensions..........................................................276 mm (L) x 100 mm (W)
X 47 mm (H)
10.8 in (L) x 3.9 in (W) x 1.9 in (H)
Weight .................................................................750 g (1.65 lbs)