EasyManua.ls Logo

Fluke 1760 - Flexi Current Sensor 200 A;1000 a

Fluke 1760
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Options and Accessories
Accessories 6
6-21
Flexi Current Sensor 200 A/1000 A
This current probe has been designed for non intrusive, accurate ac current measurements.
Using the latest technologies (internal memory for calibration data) provides current
measurements between 2 A and 1000 A. The measurement range can be selected in the
PQ Analyze software: IAC200 or IAC1000.
XW Warning
To protect against electrical shock:
Utilize the clamps only on insulated conductors, max.
600 V rms or dc to ground.
Use personal protective equipment measures as required
by local government agencies, when attaching clamps to
live circuits.
Electrical Characteristics
Nominal current In: 200 A, 1000 A AC rms
Measuring ranges: 2 A – 200 A or 10 A – 1000 A ac
Peak current: 480 A, 2700 A
Max. non destructive current: Up to 2000 A rms
Intrinsic error: < ±1 % of mv
Linearity (10 % - 100 % of In): ±0.2 % of In
Conductor position influence: < ±2 % of mv, distance to measuring head
>30 mm
Error due to adjacent conductor: ±2 A (Iext = 500 A, distance to head
>200 mm)
Phase error (to reference conditions): < ± 0.5 degrees
Temperature coefficient: 0.005 % of range/ °C
Safety: 600 V CAT IV, type B sensor, pollution
degree 2
General Specifications
Cable length: 2 m
Length of measuring head: 61 cm (24 inch)
Operating temperature range: 10 °C - +70 °C
Storage temperature range: 20 °C - +90 °C
Operating humidity: 10 % - 80 % (non condensing)
Weight: Approx. 220 g
Order-number: 2540489
Reference Conditions
Environment temperature range: +18 °C to +26 °C
Humidity: 20 – 75 %

Table of Contents

Other manuals for Fluke 1760