7
Trigger Level ........................................... 5 to 10 Hz, 10 A
10 to 100 Hz, 5 A
100 to 500 Hz, 10 A
Frequency via iFlex
Range .................................................... 5.0 to 500.0 Hz
Resolution .............................................. 0.1 Hz
Accuracy ................................................ 0.5 % ± 5 digits
Trigger Level .......................................... 5 to 20 Hz, 25 A
20 to 100 Hz, 20 A
100 to 500 Hz, 25 A
Resistance
Range ..................................................... 600 Ω/6 kΩ/60 kΩ
Resolution ............................................... 0.1 Ω/1 Ω/10 Ω
Accuracy ................................................. 1 % ± 5 digits
Mechanical Specifications
Size (L x W x H) ..................................... 277 mm *88 mm * 43 mm (55 mm for remote unit)
Weight ..................................................... 350 g
Jaw Opening ........................................... 34 mm
iFlex Diameter ......................................... 7.5 mm
iFlex Cable Length
(head to electronics connector) .............. 1.8 m
Environmental Specifications
Operating Temperature ........................... -10 °C to +50 °C
Storage Temperature .............................. -40 °C to +60 °C
Operating Humidity ................................. Non condensing (< 10 °C)
90 % RH (at 10 °C to 30 °C)
75 % RH (at 30 °C to 40 °C)
45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Operating Altitude ................................... 2000 meters
Storage Altitude ...................................... 12,000 meters
EMI, RFI, EMC, RF ................................. EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006
ETSI EN 300 489 V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381
RSS-210 IC: 6627A-F381
Temperature Coefficients........................ Add 0.1 x specified accuracy for each degree C above
28 °C or below 18 °C
Wireless Frequency ................................ 2.4 GHz ISM Band 10 meter range
Safety Compliance .................................. ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.
Double Insulation Clearance ................... Per IEC 61010-2-032
Double Insulation Creepage ................... Per IEC 61010-1
Agency Approvals ...................................