Loading...
45
Users Manual
3-6
CAL
ENABLE
V
10A
100
mA
600V CAT I
1000V CAT I
FUSE F1
500 mA
F 250V
POWER
AUTO
2ND
MN MX
RATE
dB
REL
REF# LOCAL
THRESH ADDR BAUD
HOLD
LO
HI
COMP
A
A
V
FREQ
DUAL DISPLAY MULTIMETER
45
V
!
REF
FUSED
COM
A
A
V
FREQ
V
FUNCTION BUTTONS:
-Press to Select the Function Designated
Amps AC
Volts AC
Frequency
Resistance
Diode Test/Continuity
Amps DC
Volts DC
aam13f.eps
Figure 3-5. Function Selection Buttons
Table 3-2. Voltage Ranges and Full Scale Values
Fast Reading Rate Medium Reading Rate Slow Reading Rate
Range Full Scale Range Full Scale Range Full Scale
300 mV 300.0 mV 300 mV 300.00 mV 100 mV 99.999 mV
3 V 3.000 V 3 V 3.0000 V 1000 mV 999.99 mV
30 V 30.00 V 30 V 30.000 V 10 V 9.9999 V
300 V 300.0 V 300 V 300.00 V 100 V 99.999 V
1000 V* 1000 V* 1000 V* 1000.0 V* 1000 V* 999.99 V*
* 750V for volts ac