5080A
Getting Started Manual
8
AC Voltage (Sine Wave)
Specification, tcal ±5 °C
±(% of output + μV)
Range Frequency
90 days 1 year
Resolution
Max.
Burden
[1]
Max. Distortion & Noise
10 Hz to 100 kHz
Bandwidth
[2]
±(% of output + floor)
45 to 65 Hz 0.31 % + 60 0.33 % + 60 1.00 to
32.99 mV
65 Hz to 1 kHz 0.32 % + 60 0.34 % + 60
10 μV 60 Ω 0.1 % + 300 μV
45 to 65 Hz 0.13 % + 60 0.15 % + 60 33 to
329.99 mV
[3]
65 Hz To 1 KHz 0.14 % + 60 0.16 % + 60
10 μV 60 Ω 0.1 % + 300 μV
45 to 65 Hz 0.09 % + 180 0.10 % + 180 0.33 to
3.2999 V
[3]
65 Hz to 1 kHz 0.10 % + 180 0.11 % + 180
100 μV
300 mA
0.2 % + 600 μV
45 to 65 Hz 0.09 % + 1800 0.10 % + 1800 3.3 to
32.999 V
65 Hz to 1 kHz 0.11 % + 1800 0.12 % + 1800
1 mV 800 mA 0.5 % + 6 mV
45 to 65 Hz 0.12 % + 18000 0.14 % + 18000
33 to 101.99 V
65 Hz to 1 kHz 0.13 % + 18000 0.15 % + 18000
10 mV 400 mA 0.5 % + 30 mV
45 to 65 Hz 0.12 % + 18000 0.14 % + 18000102 to
329.99 V
65 Hz to 1 kHz 0.13 % + 18000 0.15 % + 18000
10 mV 120 mA 0.5 % + 30 mV
45 to 65 Hz 0.12 % + 180000 0.14 % + 180000
330 to
1020.0 V
65 Hz to 1 kHz 0.13 % + 180000 0.15 % + 180000
100 mV 40 mA 0.5 % + 100 mV
Auxiliary Output (dual output mode only)
45 to 65 Hz 0.18 % + 1000 0.20 % + 1000
10 to
329.99 mV
65 Hz to 1 kHz 0.20 % + 1000 0.22 % + 1000
10 μV
5 mA
0.2 % + 600 μV
45 to 65 Hz 0.18 % + 1000 0.20 % + 1000
0.33 to
3.2999 V
65 Hz to 1 kHz 0.20 % + 1000 0.22 % + 1000
100 μV
5 mA
0.2 % + 600 μV
45 to 65 Hz 0.18 % + 1000 0.20 % + 1000
3.3 to 5.000 V
65 Hz to 1 kHz 0.20 % + 1000 0.22 % + 1000
1 mV 5 mA
0.2 % + 600 μV
[1] Remote sensing is not provided. Output resistance is 60 Ω for outputs <330 mV. Output resistance is <5 mΩ for outputs
0.33 V. The AUX output resistance is <1 Ω. The maximum load capacitance is 500 pF.
[2] For a resistive load. Bandwidth of 10 Hz to 10 kHz for Auxiliary Output.
[3] In dual output mode with output currents >0.33 A, the floor specification is 3X for specified outputs.