Fluke 540B - High Frequency Voltage Measurement and Calibration

Fluke 540B
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
540B
TH
ER
MA
L
TRAN
SFER
STAND
ARD
A54
B SH
UNT
•o
CABLE
6002-212860
CURRENT
T
RA
N
SFER
S
WIT
CH
o.
A40
CURRE
NT SHU
NT
AND CONNECTIONS
THE
RMA
L T
RAN
SFER
STANDAR
D
A54
SHUN
T
A
40A
SHUN
T
CABLE
6002-212852
b.
A40 A
CUR
R
ENT
SHUNT
AND CONNECTIONS
Figu
re
2-8.
CABLES
AND CONNECTIONS
FOR
CURRENT
SHUN
TS
2
-32.
HI
GH
FREQU ENCY
VOL
TAGE
MEA
SUR
EM
EN
T
AND
CALIBRA
TI
O N
2-33. GENERAL
2-34.
A
special
cable,
supplied
with
the
Model
540B,
provides
a
means
of
connecting the output of
an
external
thermal
converter
to the
HIGH
FREQ CONVERTER
jack
on the
front
panel
of
the
Model 540B
for
high
frequency
ac
voltage
measurements.
The
Fluke Model A55
Ther-
mal
Co
nv
erter
series
of
nine
high
frequency
thermal
converters
are
supplied
in
ranges
identica
l
with
the
Model 540B
ranges
up
to
and
including 50
volts.
These
conve
rters
make
accurate
measurements
up
to 50 MHz
possible.
When
using
external
thermal
converters
the
internal
t
hermocouple,
range
switch,
transfer
switch,
search
and
protection
circuits
are
not
used.
Since
no
protection
is
provided
for
the
external
thermal
converter
it
will
be
necessary
to
use
all
normal
cautions
to
avoid
overloads. The i
nstruction
manual f
or
the
A55
Thermal
Converters
should
be
used
to obtain the
correction
factor
due to
transmission
line
effect
s.
CA
UTION!
Always
use
a
thermal
converter
whose r
ated
val
ue
is
equal
to
or
greater
t han
the
rms
value
of
the
ac
voltage
to
be
measured.
If
the
approximate
value
of
the
ac
voltage
is
unkno
w
n,
mea
sure
with
a
high
frequency
voltmeter
b
efore
connecting
to
the t
hermal
co
nvert
er.
2-35
. MEASURING AN
UNKNOWN
HIGH FREQUENCY
VOLTAGE
2-36. Comple
te
the
Battery
Check of
Figure
2-4.
Re-
move
th
e
pl
ug
fr
om
the
HIGH
FREQ
CONVERTER
jack
on
th
e
Model
540B.
Connect
the
se
l
ec
t
ed
Model
A55
Thermal
Converter
output
to
th
e HIGH
FREQ
CO
N-
VERTER
jack
u
sing
the
interconnecting
cable, sup
pli
ed
2-
10
with
the
Model 540B.
This
cable
allows
the
external
converter
to
be
connected
close
to
the
ac
being
meas
-
ured,
thus
reducing
transmission
line
effects.
Connect
the
thermal
converter
to
the
ac
source
to
be
measured.
The
voltage
may
be
1/2
to
1
times
the
rated
value
of
the
converter.
Use
the
procedure
in
Figure
2-11.
Note!
Depending
on
how
the
Model
A55
Thermal
Convert
er
is
co
nnected
to
the
source
of
the
unknown vo
ltag
e,
it
may
be
necessary
to
make
correct
ions
for
standing
waves
at
frequencie
s
above
5 MHz. See
the
Model
A55
Th
e
rmal
Converter
manual
for
further
information.
2-37. CALIBRATING A
HIGH
FREQUENCY VOLTAGE
SOURCE
2-38.
Complete
the
Battery
Check of F
igure
2-4.
Re-
move
the
plug f
rom
the
H
IGH
FREQ
CONVERTER
jack
on
the
Model
540B
front
panel.
Connect
the
selected
Model A55
Thermal
Converter
output
to
the
HIG
.H FREQ
CONVERTER
jack
u
sing
the interconnecting cable,
sup-
plied
with t he
Model
540B.
This
cable
allows
the
ex-
t
ernal
converter
to
be
connected
close
to
the
ac
being
calibra
t
ed,
thus
reducing
tra
nsmissio
n
line
effects
.
Conn
ec
t
the
thermal
converter
to
the
ac
source
to
be
calibrated.
The voltage may
be
1/2
to
1
times
the
rated
v
alue
of
the
converter.
Use
th
e
procedure
in
Figure
2-12.
Note!
If
the
input
impedan
ce
of
the
instrument
being
calibrated
is
not
50
ohms
,
it
may
be
necessary
to
corre
ct
for
the
standing wave
between
th
e
center
of
the
tee
and
the
instru-
ment
being
calibrated
at
frequenc
i
es
above
5 MHz. See
the
Model A55
Thermal
Con-
v
er
t
er
m
anual
for
further
information.