EasyManuals Logo

Fluke 8846A User Manual

Fluke 8846A
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
4-1
Chapter 4
Making Measurements
Title Page
Introduction........................................................................................................ 4-3
Selecting Function Modifiers............................................................................. 4-3
Activating the Secondary Display ..................................................................... 4-3
Measuring Voltage............................................................................................. 4-4
Measuring DC Voltage.................................................................................. 4-4
Measuring AC Voltage.................................................................................. 4-5
Measuring Frequency and Period ...................................................................... 4-7
Measuring Resistance ........................................................................................ 4-7
Making a Two-wire Resistance Measurement .............................................. 4-8
Making a Four-wire Resistance Measurement .............................................. 4-8
Measuring Current ............................................................................................. 4-10
Measuring DC Current .................................................................................. 4-11
Measuring AC Current .................................................................................. 4-12
Measuring Capacitance (8846A only) ............................................................... 4-13
Measuring RTD Temperature (8846A only) ..................................................... 4-14
Testing Continuity ............................................................................................. 4-15
Checking Diodes................................................................................................ 4-16
Making a Triggered Measurement..................................................................... 4-17
Setting the Trigger Mode............................................................................... 4-17
Setting a Trigger Delay ................................................................................. 4-17
Setting Number of Samples per Trigger........................................................ 4-18
Connecting an External Trigger .................................................................... 4-18
Monitoring the Measurement-Complete Signal................................................. 4-18

Table of Contents

Other manuals for Fluke 8846A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 8846A and is the answer not in the manual?

Fluke 8846A Specifications

General IconGeneral
Frequency Range3 Hz to 300 kHz
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Resistance Range10 Ω to 1 GΩ
ContinuityYes
Diode TestYes
Temperature MeasurementYes
Display5.5 digit
ConnectivityUSB, RS-232, GPIB
DC Current Range100 µA to 10 A
AC Current Range100 µA to 10 A
Frequency Accuracy0.01 %
Capacitance Range1 nF to 100 µF
Display TypeVFD
Power Supply100 V to 240 V
AC Voltage Accuracy±(0.06% + 0.03% of reading)
Resistance Accuracy±(0.01% + 0.001% of reading)

Related product manuals