EasyManua.ls Logo

Fluke CombiScope PM3370B - Page 166

Fluke CombiScope PM3370B
297 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 - 66 COMMAND REFERENCE
INSTrument:NSELect
INSTrument[:SELect]
Syntax:
INSTrument:NSELect <NRf> | MINimum | MAXimum
INSTrument[:SELect] DIGital | ANALog
<NRf> 1 | 2
1 | MINimum The digital mode (ANALOG key) is activated.
2 | MAXimum The analog mode is activated.
DIGital The digital mode (ANALOG key) is activated.
ANALog The analog mode is activated.
Query form:
INSTrument:NSELect? [MINimum | MAXimum}
Response:
1 | 2
1 The digital mode (ANALOG key) is active. This is
also returned when MAXimum is specified.
2 The analog mode is active. This is also returned
when MINimum is specified.
Query form:
INSTrument[:SELect]?
Response:
DIG | ANAL
DIG The digital mode (ANALOG key) is active.
ANAL The analog mode is active.
Description:
Selects the analog or digital mode of the CombiScope by specifying a predefined
number or name. When one mode is selected, the other mode is deactivated.
After a
*
RST command, the digital mode (ANALOG key) is selected.
Example:
Send
INSTrument:NSELect 2 Analog mode is selected.
Send
INSTrument DIGital Digital mode is selected.
Front panel compliance:
These commands are the remote equivalent of the front panel ANALOG key.

Table of Contents