EasyManuals Logo

Fluke SimpliFiber User Manual

Fluke SimpliFiber
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
S IMPLIFIBER ENGLISH - 22
requires the reference value to compensate for
the signal loss in the launch cable. This value
is then automatically subtracted from the
actual measured value to determine cable
plant loss.
Note
The launch cable used to set the reference
value should be the same type as the cables to
be tested: 50/125, 62.5/125, or single-mode.
IMPORTANT
All connectors and fiber end faces
should be cleaned prior to testing.
The Reference Methods
There are three recognized methods for
reference determination. Reference diagrams
will show how to establish a reference for
each method.
It is very important that the connections are
not disturbed after the reference value is
established. To assure that the effects of the
connectors and launch cables are zeroed
out, follow the instructions closely.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke SimpliFiber and is the answer not in the manual?

Fluke SimpliFiber Specifications

General IconGeneral
BrandFluke
ModelSimpliFiber
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals