FUEL PRESSURE GAUGE SETUP
Max
: set the top limit of the fuel pressure gauge.
High
: set the transition pressure from green to high red zone of the fuel pressure gauge.
Low
: set the transition pressure from low red to green zone of the fuel pressure gauge.
Min
: set the bottom limit of the fuel pressure gauge.
VOLT GAUGE SETUP
Max
: set the top limit of the voltage gauge.
High
: set the transition voltage from green to high red zone of battery voltage.
Low
: set the transition voltage from low red to green zone of battery voltage.
Min
: set the bottom limit of the voltage gauge.
AMP GAUGE SETUP
Max
: set the top limit of the current meter gauge.
Low
: set the transition voltage from yellow to green zone of the current meter gauge.
Min
: set the bottom limit of the current meter gauge.
ASI GAUGE SETUP
NOTE:
The default speed are all set to zero. Its mandatory to check your aircraft characteristics speed and set the following
parameters accordingly.
Vne-Vno-Vfe-Vs-Vs0
: Set the speed setpoint for the moving tape airspeed indicator (see next picture).
Vy :
Set the Vy of your aircraft.
Vx :
Set the Vx of your aircraft.
Unit :
Set the unit of measure for the air speed indicator in kilometers per hour (Km/h), miles per hour (Mph) or knots (Kts).