EasyManua.ls Logo

FONESTAR MPX-4088 - DUCKER FUNCTION DETAILS; FEEDBACK CANCELLER FBC; FBC Input Select; FBC Setting

FONESTAR MPX-4088
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BGM Setting
2
.- Local input: selection of input channels to be attenuated.
3
.- Network Input: selection of broadcast inputs to be attenuated.
D
ucking Controller
4.- Threshold: attenuation threshold.
5.- Depth: attenuation depth.
6.- Attack: reaction time to attenuate the selected channels.
7.- Release: release time of the selected channels.
8.- Default: resets the default values.
9.- Bypass: the input signal is not processed and is diverted to the next processing module.
FEEDBACK CANCELLER FBC
The Feedback Canceller function automatically eliminates the feedback produced by microphones to nearby
loudspeakers.
FBC Input Select
1.- Local Input: selection of input channels to be processed.
2.- Network input: selection of broadcast input channels to be processed.
FBC Setting
3.- Filter Release: dynamic filter release time after processing the signal.
4.- FBC Mode: application mode, for music or for speech.
FBC Setup
5.- Static Filters Setup: volume configuration to achieve feedback.
6.- FBC filters: 24 feedback cancellation filters.
7.- Clear Dynamic Filters: restarts dynamic filters.
8.- Clear All Filters: restarts all filters, static and dynamic.
9.- Bypass: the input signal is not processed and is diverted to the next processing module.
- 14 -