RAID CONFIGURATION
89
Example๎2.๎Reset๎a๎RAID5๎system
1.๎A๎TryRAID5๎volume๎was๎built๎with๎three๎hard๎disks,๎we๎want๎to๎reset๎one๎of๎them.๎Select๎โ3.๎๎
Reset Disks to Non-RAIDโ in main menu and press <Enter>.
Intel(R)๎Matrix๎Storage๎Manager๎option๎ROM๎v5.0.0.1011๎ICH9R๎wRAID5
๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎Copyright(C)๎2003-04๎Intel๎Corporation๎All๎Rights๎Reserved.
๎ ๎ 1.๎Create๎RAID๎Volume๎๎ ๎ 4.๎Recover๎Volume๎Options
๎ ๎ 2.๎Delete๎RAID๎Volume๎ ๎ 5.๎Acceleration๎Option๎ ๎
6. Exit
RAID Volume :
ID Name Level Stripe Size Status Bootable
๎ 0๎ TryRAID5๎ ๎ RAID5(Parity)๎๎๎๎๎64KB๎ 149.1GB๎ Normal Yes
Physical Disks:
Port Drive Model Serial # Size Type/Status(Vol ID)
๎ 0๎ Hitachi๎HDS72161๎ PVF904Z21G2JZM๎ 149.0GB๎ Member Disk(0)
1
ST380811AS
5PS1TAGW๎ 74.5GB๎ Member Disk(0)
๎ 2๎
SAMSUNG HD161HJ
๎ S0V3J9APA30524๎ 149.0GB๎ Member Disk(0)
3
ST380815AS๎
5RW1CA37
๎ 74.5GB๎ Non-RAID Disk
Intel(R)๎Rapid๎Storage๎Technology๎๎-๎๎Uption๎ROM๎-๎11.0.8.1204๎๎๎๎๎๎๎๎๎๎๎๎๎
Copyright(C)๎2003-11๎Intel๎Corporation.๎๎๎All๎Rights๎Reserved.
[๎DISK/VOLUME๎INFORMATION ]
[ MAIN MENU ]
๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎[โโ]-Select๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎[ESC]-Exit๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎[ENTER]-Select๎Menu
3. Reset Disks to Non-RAID
2.๎A๎warning๎message๎is๎displayed.
3.๎Select๎โPort๎2๎-๎SAMSUNG๎HD161HJโ๎hard๎disk๎as๎the๎one๎to๎be๎reset.๎Press๎<Enter>.๎A๎๎
๎ double๎con๎ฟrmation๎message๎pops๎out,๎press๎<Y>๎to๎con๎ฟrm.
Intel(R)๎Matrix๎Storage๎Manager๎option๎ROM๎v5.0.0.1011๎ICH9R๎wRAID5
๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎Copyright(C)๎2003-04๎Intel๎Corporation๎All๎Rights๎Reserved.
1. Create RAID Volume 3. Reset Disks to Non-RAID
๎ ๎ 2.๎Delete๎RAID๎Volume๎ ๎ 5.๎Acceleration๎Options
3. Reset Disks to Non-RAID 6. Exit
RAID Volume :
ID Name Level Stripe Size Status Bootable
๎ 0๎ TryRAID5๎ ๎ RAID5(Parity)๎๎๎๎๎64KB๎ 149.1GB๎ Normal Yes
Physical Disks:
Port Drive Model Serial # Size Type/Status(Vol ID)
๎ 0๎ Hitachi๎HDS72161๎ PVF904Z21G2JZM๎ 149.0GB๎ Member Disk(0)
1
ST380811AS
5PS1TAGW๎ 74.5GB๎ Member Disk(0)
๎ 2๎
SAMSUNG HD161HJ
๎ S0V3J9APA30524๎ 149.0GB๎ Member Disk(0)
3
ST380815AS๎
5RW1CA37
๎ 74.5GB๎ Non-RAID Disk
Intel(R)๎Rapid๎Storage๎Technology๎๎-๎๎Uption๎ROM๎-๎11.0.8.1204๎๎๎๎๎๎๎๎๎๎๎๎๎
Copyright(C)๎2003-11๎Intel๎Corporation.๎๎๎All๎Rights๎Reserved.
[๎DISK/VOLUME๎INFORMATION ]
[ MAIN MENU ]
1. Create RAID Volume
๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎[โโ]-Select๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎[ESC]-Exit๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎๎[ENTER]-Select๎Menu
[โโ]-Previous/Next๎๎๎๎๎๎๎[SPACE]-Selects๎๎๎๎๎๎๎[ENTER]-Selection๎Complete
Resetting RAID disk will remove its RAID structures
and revert it to a non-RAID disk.
WARNING: Resetting a disk causes all data on the disk to be lost.
( This does not apply to Recovery volumes)
Port Drive Model Serial # Size Status
0๎ Hitachi๎HDS721616PLA
PVF904Z21G2JZM๎ 149.0GB๎ Member๎Disk
1
ST380811AS
๎ 5PS1TAGW๎ 74.5GB๎ Member๎Disk
โบ๎2๎
SAMSUNG
๎ S0V3J9APA30524๎ 149.0GB๎ Member๎Disk
Select the disks that should be reset.
[โโ]-Previous/Next๎๎๎๎๎๎๎[SPACE]-Selects๎๎๎๎๎๎๎[ENTER]-Selection๎Complete
[ RESET RAID DATA ]
2๎๎ SAMSUNG๎HD161HJ๎ S0V3J9APA30524๎ 149.0GB๎Member๎Disk
4.๎A๎"DEGRADED๎VOLUME๎DETECTED"๎screen๎pops๎out๎asking๎you๎to๎select๎a๎new๎hard๎disk๎๎
๎ for๎rebuilding.๎Here,๎we๎select๎ST๎74.5GB.๎Press๎<Enter>๎to๎select๎it.๎