Page 9
7.
Regenerant tanks should be accessible for easy refilling. If the control valve is to be used to regenerate the water conditioner with
brine (saturated salt solution) or other regenerants, use a polyethylene tube to connect the brine valve contained in the regenerant
tank to the regenerant port on the control valve. It is recommended the brine valve contain a safety float. The 1.5” control valve’s
regenerant port has a ½” fitting. Note: ½” tubing that runs longer than 6 feet may restrict draw rates with G and H injectors. A
5/8” fitting is also available.
The 2” control valve regenerant port has a 1” threaded connection. To ensure acceptable operation of the injectors, use 1” pipe to
connect to the brine tank.
An overflow drain line from the regenerant tank that discharges into an acceptable drain is recommended, as a regenerant
overflow could damage furnishings or the building structure. Connect a line to the overflow fitting on the regenerant tank. If an
overflow fitting is not already installed on the regenerant tank, install one. Do not elevate the overflow drain line. Discharge the
overflow drain line through an air gap to a receptacle in accordance with local plumbing codes.
8.
Program the control valve: It is very important to program the control valve for the type of system (e.g. water softener or filter.)
Consult your OEM for proper program system settings.
9.
The use of resin cleaners in an unvented enclosure is not recommended.