Operating Instructions
Reactive Power Control Relay RM 9606

Other manuals for frako RM 9606

Question and Answer IconNeed help?

Do you have a question about the frako RM 9606 and is the answer not in the manual?

frako RM 9606 Specifications

General IconGeneral
Contact Current8 A
Contact Voltage AC250 V
TypeTime relay
Contact ConfigurationSPDT
Mounting TypeDIN Rail
Operating temperature-20 °C to +55 °C

Summary

Safety and Warning Instructions

General Safety Precautions

Essential safety guidelines and warnings for handling and operating the control relay, emphasizing trained personnel and caution.

Installation and Connection

Current Transformer Connection

Guidance on connecting the current transformer outputs to the relay terminals, including wire cross-section and current limits.

Commissioning

First Commissioning Process

Process for initial start-up, including automatic identification of connection and stage sizes, and troubleshooting steps.

Programming (Set)

Programming Modes - Core Settings

Target Power Factor and Parallel Shift

Details on setting target power factor (0.90 to 0.80) and parallel shift (-2 to +4).

Limitation, Time Delay, c/k Identification

Settings for limitation (-2 to +2), switching time delay (5-500s), and automatic c/k identification.

Programming Modes - Connectivity and Switching

Connection Identification and Switching Settings

Configuration for automatic/manual connection, switching-off time, cyclic/non-cyclic rotation, and switching alarm thresholds.

Counter Reset and Transformer Ratios

Settings for resetting switching counters and inputting current/voltage transformer ratios.

Programming Modes - Harmonics and Alarms

Harmonic Thresholds and Over-Current Alarms

Setting alarm thresholds for 5th, 7th, 11th, and 13th harmonics and harmonic over-current alarm.

Power Factor Alarm Suppression and kvar Display

Configuration for suppressing power factor alarms and enabling total kvar display.

Target Power Factor Setting

Parallel Shift (PS) Functionality

Explains how parallel shift settings affect the control band and provides examples with figures.

Parallel Shift Settings and Effects

Details how parallel shift affects the control band and illustrates its use with examples.

Limitation (L) Setting and Behavior

Details the 'Limitation' setting, its range, and how it affects control characteristics, including 'kinked' behavior.

Switching Time Delay Configuration

Configures the delay between switching operations to minimize contactor wear, with examples for multiple stages.

Switching Sequence and Stage Configuration

Advanced Programming Settings - Part 1

Advanced Programming Settings - Part 2

Advanced Programming Settings - Part 3

Operation

Manual Operation Mode Activation

Enters manual mode for switching capacitor stages ON/OFF using '+' and '-' buttons.

Alarm System Overview and Acknowledgement

General overview of alarm conditions, LED indicators, acknowledgment, and their impact on control behaviour.

Trouble-Shooting

Display and Operation Faults

Addresses faults like blank display, U=0, no response to manual operation, and stage display issues.

Identification and Connection Faults

Covers faults during identification, C=0, I=0, and checks for correct current transformer connection.

Automatic Mode and Load Control Faults

Deals with problems like no stages switched on in automatic mode, stage hunting, and load control issues.