84
Problem Solution
Temperature
sensor reads too
high in the day
time.
Make certain that the sensor array is not too close to
heat generating sources or strictures, such as
buildings, pavement, walls or air conditioning units.
Use the calibration feature to offset installation
issues related to radiant heat sources. Reference
Section 6.7.
Relative pressure
does not agree
with official
reporting station
You may be viewing the absolute pressure, not the
relative pressure.
Select the relative pressure. Make sure you properly
calibrate the sensor to an official local weather
station. Reference Section 6.4.6 for details.
Rain gauge reports
rain when it is not
raining
An unstable mounting solution (sway in the
mounting pole) may result in the tipping bucket
incorrectly incrementing rainfall. Make sure you
have a stable, level mounting solution.
Data not reporting
to Wunderground.
com
1. Confirm your password or key is correct. It is
the password you registered on
Wunderground.com. Your
Wunderground.com password cannot begin
with a non-alphanumeric character (a
limitation of Wundeground.com, not the
station). Example, $oewkrf is not a valid
password, but oewkrf$ is valid.
2. Confirm your station ID is correct. The
station ID is all caps, and the most common
issue is substituting an O for a 0 (or visa

Table of Contents