6.6 Sealing the straps,
Operation mode Manual
• Press and release immediately the sealing button.
The plastic strap is welded and cut off from the rest of
the strap.
During the welding the LED lights green.
After elapsing of the adjusted welding time (see
6.2.2) the cooling time begins (LED lights yellow).
During that time the tool must not be removed from
the strap.
6.7 Tensioning and sealing the strap
Operation mode Semi-Automatic
• Push tension button until the adjusted tension
force is reached.
During tensioning the LED lights green.
The tensioning operation can be interrupted and
restarted at any time.
After reaching the adjusted strap tension the sealing
cycle is initiated automatically (LED lights blue).
Welding gripper is lowered,
the welding starts (LED lights green).
• Release the tension button after the sealing
process has been started.
The plastic strap is welded and cut off from the rest of the strap.
After elapsing of the adjusted welding time (see 6.2.2) the cooling time begins (LED lights yellow).
The tool must not be removed from the strap as long as the cooling time is not
finished. Disregard of this regulation is causing insufficient seal efficiencies, which
can cause severe injuries.
6.8 Removing the tool
After the cooling time is elapsed an acoustic signal
happens and the LED lights green again. The sealing
process is finished.
• Pull up the handle lever,