NOTE!
The contact pressure is set as follows:
Turn screw clockwise = reduce the contact pressure,
maximum load moment = gently as far as stop - turn the screw until the contact
pressure indicator is in the 'min' position
Turn screw anti-clockwise = increase the contact pressure,
maximum load moment = 0.4 Nm - turn the screw until the contact pressure indica-
tor is in the 'max' position