10
Adjusting the
PTW 500 tungs-
ten electrode
(continued)
Adjusting the
PTW 1500 tungs-
ten electrode
Loosen the torch cap - caution, the tungsten
electrode may fall out of the plasma torch if the
torch is in a particular position.
Place adjusting gauge onto plasma nozzle ...
5
1
6
2
1
3
Setting the adjusting gauge to measurement „x“
NOTE! The standard setting for
measurement „x“ on the adjusting
gauge depends on the diameter
of the plasma nozzle. Refer to the
following table when adjusting the
standard setting for measurement
„x“:
∅ ∅
∅ ∅
∅ Plasma „x“ Adjusting
nozzle gauge
1.0 mm - -
1.5 mm 1.5 mm ∅ 1.5 - 2 mm
2.0 mm 2.0 mm ∅ 1.5 - 2 mm
2.5 mm 2.5 mm ∅ 2.5 - 3 mm
3.0 mm 2.5 mm ∅ 2.5 - 3 mm
Calibrating the
PTW 1500 adjus-
ting gauge