38
Delay:
charge start delay:
Delay time (minutes) of actual start of charging relative to the moment when charge start
was initiated
charge end delay:
Delay time (minutes) before charge end is signalled (e.g. green indicator) relative to the
moment when charging actually stopped
at mains failure restart charging:
If this option is selected, the charging process is restarted automatically as soon as the
mains supply becomes available again after a disruption to the electrical mains supply.
Calendar:
The calendar function allows charging to be started automatically according to the follow-
ing criteria:
- Time window in which charging may not be started if a battery is connected
- Time window in which charging is to be started using a defined characteristic 1 if a bat-
tery is connected
- Time window in which charging is to be started using a defined characteristic 2 if a bat-
tery is connected
To activate the calendar function,
select the "ON" setting and confirm
The first menu item "Charging settings" al-
lows three characteristics to be defined:
- Type of battery for every characteristic:
e.g. Pb-Wet
- Curve settings when selecting the rele-
vant characteristic
1