DC input data
Limit value and tripping time of the
continuous residual current monitor-
ing (on delivery)
300 / 300 mA / ms
Adjustable range of continuous resid-
ual current monitoring
9)
30 – 300 mA
Cyclic repetition of the insulation res-
istance test (on delivery)
24 h
Adjustable range for the cyclic repeti-
tion of the insulation resistance test
-
DC input data, battery
8)
Max. voltage
11)
531 V
Min. voltage 160 V
Max. current 22 A
Max. output 12,000 W
DC inputs 1
AC input/output data
Rated power (P
nom
) 12,000 W
Max. output power 12,000 W
Rated apparent power 12,000 VA
Nominal grid voltage 3 ~ NPE 220 V / 380 V
3 ~ NPE 230 V / 400 V
Min. grid voltage
154 V
1)
Max. grid voltage
280 V
1)
Max. output current 18.5 A
Nominal output current (at 230 V) 17.4 A
Current (inrush)
6)
9.9 A / 4 ms
Nominal frequency
50/60 Hz
1)
Initial short circuit alternating cur-
rent / phase I
K
18.5 A
Nominal frequency for Full Backup
53/63 Hz
1)
Total harmonic distortion < 3.5%
Power factor cos phi
2)
0 – 1 (adjustable)
0.7 – 1 (recommended)
Max. permitted mains impedance Z
max
on PCC
4)
None
Maximum output fault current / dura-
tion
80.7 A / 10 ms
AC output data PV Point / PV Point Comfort
Max. output power 4255 W (for 5 s)