9
Technical Data
Note! If the machine is designed to run on a special voltage, the Technical Data
shown on the rating plate apply. The mains plug and mains supply lead, and
their fuse protection, must be dimensioned accordingly.
Technical Data
Mains voltage 3 x 400 V~, 50 - 60 Hz
Mains fuse 10 A slow
Cos phi (150 A) 0.99
Efficiency (200 A) 88 %
Welding current range El - DC 20 - 200 A
Welding current at 10min / 40°C 40 % d.c. 200 A
10min / 40°C 100% d.c. 130 A
Apparent power at 40 % d.c. 7.8 kVA
100% d.c. 4.7 kVA
Open-circuit voltage (400 V) 90 V
Operating voltage Electrode 20.8 - 28 V
Protection class IP 23
Type of cooling AF
Insulation category B
Approval marks S, CE