HIGH PRODUCTION RE (HPRE) E
4
SERIES ELECTRIC FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
2-3
NOTICE
If the electrical power supply cord is damaged, it must be replaced by a Frymaster Factory
Authorized Servicer technician or a similarly qualified person in order to avoid a hazard.
DANGER
This appliance must be connected to a power supply having the same voltage and phase as
specified on the rating plate located on the inside of the appliance door.
DANGER
All wiring connections for this appliance must be made in accordance with the wiring
diagram(s) furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside
of the appliance door when installing or servicing this equipment.
WARNING
Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over
and cause injury. The appliance area must be kept free and clear of combustible material at
all times.
In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the
power switch "OFF". Do not attempt to start the fryer(s) until power is restored.
2.1.1 Clearance and Ventilation
This appliance must be kept free and clear of combustible material, except that it may be installed on
combustible floors.
A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible
construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for
servicing and proper operation.
WARNING
Do not block the area around the base or under the fryers.
DANGER
No structural material on the fryer should be altered or removed to accommodate placement
of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-
8633.
When installing any type of fryer, Standard No. 96 of the National Fire Protection Association must
be followed implicitly.
The duct system, the hood and filter bank must be cleaned on a regular basis and kept free of grease
according to the NFPA Standard No. 96.
A copy of the standard may be obtained from the National Fire Protection Association, Battery
March Park, Quincy, MA 02269 or at www.NFPA.org.