Semi-standard Specifications
Momentary voltage dip capability *5)
EMC filter built-in type
Three-phase series
Type (FRN
C1E-
U)
Applicable motor rating *1) 1/8 1/4 1/2 1 2 3 5 1/2 1 2 3 5
Enclosure (IEC 60529)
Cooling method
Weight / Mass
IP20, UL open type *11)
Natural cooling Fan cooling Natural cooling Fan cooling
Rated capacity *2) 0.31 0.59 1.1 1.9 3.1 4.3 6.7 1.1 1.9 2.9 4.3 7.1
Rated current *4)
0.8
(0.7)
1.5
(1.4)
3.0
(2.5)
5.0
(4.2)
8.0
(7.0)
11.0
(10.0)
17.0
(16.5)
1.5 2.5 3.7 5.5 9.0
Rated voltage *3)
Overload capability 150% of rated current for 1min, 200% of rated current for 0.5s
Rated frequency
Phases, voltage, frequency Three-phase, 200 to 240V, 50/60Hz Three-phase, 380 to 480V, 50/60Hz
Voltage/frequency variations
Required power supply capacity *7) 0.2 0.3
1.5(0.7) 1.5(0.7) 1.5(0.7) 1.8(0.8) 5.3(2.4) 5.3(2.4) 6.4(2.9) 3.3(1.5) 3.7(1.6) 5.5(2.5) 5.5(2.5) 6.6(3.0)
0.6 1.1 2.0 2.9 4.9 0.6 1.1 2.0 2.9 4.9
Torque *8) 150 100
50 30 100 50 30
Torque *9)
DC injection braking
- 150 150
Starting frequency: 0.0 to 60.0Hz Braking time: 0.0 to 30.0s Braking level: 0 to 100% of rated current
Voltage: +10 to -15% (Voltage unbalance *10) : 2% or less) Frequency: +5 to -5%
Rated current *6)
(with DCR)
(without DCR)
0.57
1.1
0.93
1.8
1.6
3.1
3.0
5.3
5.7
9.5
8.3
13.2
14.0
22.2
0.85
1.7
1.6
3.1
3.0
5.9
4.4
8.2
7.3
13.0
50, 60Hz
Three-phase, 200V/50Hz, 200, 220, 230V/60Hz
Three-phase, 380, 400, 415V/50Hz, 380, 400, 440, 460V/60Hz
Input power source
FRNF12
C1E-2U
FRNF25
C1E-2U
FRNF50
C1E-2U
FRN001
C1E-2U
FRN002
C1E-2U
FRN003
C1E-2U
FRN005
C1E-2U
FRNF50
C1E-4U
FRN001
C1E-4U
FRN002
C1E-4U
FRN003
C1E-4U
FRN005
C1E-4U
Three-phase 230V
Item Specifications
Three-phase 460V
Output ratingsInput ratingsBraking
Type (FRN
C1E-
U)
Applicable motor rating *1) 1/8 1/4 1/2 1 2 3
Enclosure (IEC 60529)
Cooling method
Weight / Mass
IP20, UL open type *11)
Natural cooling Fan cooling
Rated capacity *2) 0.31 0.59 1.1 1.9 3.1 4.3
Rated current *4)
0.8
(0.7)
1.5
(1.4)
3.0
(2.5)
5.0
(4.2)
8.0
(7.0)
11.0
(10.0)
Rated voltage *3)
Overload capability 150% of rated current for 1min, 200% of rated current for 0.5s
Rated frequency
Phases, voltage, frequency Single-phase, 200 to 240V, 50/60Hz
Voltage/frequency variations
Required power supply capacity *7) 0.3 0.4 0.7 1.3 2.4 3.5
1.5(0.7) 1.5(0.7) 1.5(0.7) 2.6(1.2) 5.3(2.4) 6.4(2.9)
Torque *8) 150 100 30
50
Torque *9)
DC injection braking
-
150
Starting frequency: 0.0 to 60.0Hz Braking time: 0.0 to 30.0s Braking level: 0 to 100% of rated current
Voltage: +10 to -10%, Frequency: +5 to -5%
Momentary voltage dip capability *5)
Rated current *6)
(with DCR)
(without DCR)
1.1
1.8
2.0
3.3
3.5
5.4
6.4
9.7
11.6
16.4
17.5
24.8
When the input voltage is 165V or more, the inverter continues operation. If it drops below 165V,
the inverter operates for 15ms.
50, 60Hz
Three-phase, 200V/50Hz, 200, 220, 230V/60Hz
Input power source
FRNF12
C1E-7U
FRNF25
C1E-7U
FRNF50
C1E-7U
FRN001
C1E-7U
FRN002
C1E-7U
FRN003
C1E-7U
Single-phase 230V
Item Specifications
Output ratingsInput ratingsBraking
kVA
A
%
%
lbs.(kg)
A
HP
kVA
kVA
V
A
%
%
lbs.(kg)
HP
kVA
A
Max voltage [V] - Min voltage [V]
Three-phase average voltage [V]
x 67 (IEC 61800-3 (5.2.3))
Single-phase series
When the input voltage is 165V or more, the inverter continues operation. If it
drops below 165V, the inverter operates for 15ms.
When the input voltage is 300V or more, the inverter
continues operation. If it drops below 300V, the
inverter operates for 15ms.
*10) Voltage unbalance [%] =
If this value is 2 to 3%, use AC REACTOR (ACR).
*11) NEMA1 kit (option) is required for the enclosure conforming to the UL standard TYPE1 (NEMA1).
Use the inverter in the ambient temperature range from -10 to +40
°C (14 to 104°F)
.
*12) When driven by 100 VAC, the single-phase 115 V class series of inverters limit their shaft output and maximum
output torque as listed below. This is to prevent their output voltage from decreasing when load is applied.
Shaft output (%) Maximum torque (%)
w/o DC reactor (DCR) 90 150
w/ DC reactor (DCR) 85 120
9