EasyManua.ls Logo

Fuji Electric frenic mini series - Single-Phase 230 V

Fuji Electric frenic mini series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Options
Wiring equipment
Options
SC-05
FRNF12C1
-2U**
FRNF25C1
-2U**
FRNF50C1
-2U**
FRN001C1
-2
U**
FRN002C1
-2U**
FRN003C1
-2U**
FRN005C1
-2U**
1/8
1/4
1/2
1
2
3
5
5
10
20
5
10
15
20
30
SC-05 SC-05
SC-5-1
2.0 2.0 2.0 2.0
2.0
SC-05
FRNF12C1-7U
FRNF12C1-6U
FRNF25C1
-6
U
FRNF50C1
-6U
FRN001C1
-6U
1/8
1/8
1/4
FRNF25C1
-7U
FRNF50C1
-7U
FRN001C1
-7
U
1/4
1/2
1
1/2
1
FRN002C1
-7U
FRN003C1
-7U
2
3
5
5
10
15
10
15
20
5
5
10
15
20
10
15
20
30
SC-05
SC-05
SC-05
SC-05 SC-05
SC-5-1
2.0
2.0
2.0
2.0
3.5
2.0 2.0
2.0 2.0
2.0
2.0
FRNF50C1-4U**
FRN001C1
-4
U**
FRN002C1
-4U**
FRN003C1
-4U**
FRN005C1
-4U**
1/2
1
2
3
5
5
10
5
10
15
20
SC-05 SC-05 SC-05 2.0 2.0 2.0 2.0 2.0
Name Dimension
[Unit : inch (mm)]
DC REACTOR
Note)
For the inverter type FRNF50C1-2U**, the symbol is replaced with either of the following alphabets and ** is replaced with any of the following numeral codes:
: S (Standard type), E (EMC filter built-in type), ** : 21 (Braking resistor built-in type), None (Standard type)
The inverter applicable to RS-485 communication is limited to the standard ones in three-phase 230V and three-phase 460V series.
The braking resistor built-in type is limited to the inverters for 2HP or larger.
Note)
For the inverter type FRNF50C1-2U**, the symbol is replaced with either of the following letters and ** is replaced with any of the following numeral codes:
: S (Standard type), E (EMC filter built-in type), ** : 21 (Braking resistor built-in type), None (Standard type)
The inverter applicable to RS-485 communication is limited to the standard ones in three-phase 230V and three-phase 460V series.
The braking resistor built-in type is limited to the inverters rated 2HP or larger.
For molded-case circuit breakers (MCCB) and a ground-fault circuit interrupter (GFCI), the required frame type and series depend on the facility transformer capacity and other
factors. When selecting optimal breakers, refer to the relevant technical data. Also select the rated sensitive current of GFCI utilizing the technical data. The above rated currents
of MCCB and GFCI are for the breakers SA
B/
and SA
R/
.
The recommended wire sizes are based on the temperature inside the panel not exceeding 50°C (122°F).
The above wires are 600V HIV insulated solid wires (75°C (167°F)).
Data in the above table may differ according to environmental conditions (ambient temperature, power supply voltage, and other factors).
E
H
C
D
B
A
4-G Mounting hole
Three-phase
230V
Single-phase
230V
Single-phase
115V
ABCD E G H
FRNF12C1-2U**
FRNF25C1-2U**
FRNF50C1-2U** FRNF25C1-7U DCR2-0.4 0.59(15) 2.21(1.0)
FRN001C1-2U** FRNF50C1-7U FRNF12C1-6U DCR2-0.75
M4
3.09(1.4)
FRN002C1-2U** FRN001C1-7U FRNF25C1-6U DCR2-1.5 3.53(1.6)
FRN003C1-2U** FRN002C1-7U FRNF50C1-6U DCR2-2.2
0.39(10)
3.97(1.8)
FRN005C1-2U** FRN003C1-7U FRN001C1-6U DCR2-3.7 0.79(20) 5.73(2.6)
FRNF50C1-4U** DCR4-0.4 0.59(15) 2.21(1.0)
FRN001C1-4U** DCR4-0.75
M4
3.09(1.4)
FRN002C1-4U** DCR4-1.5 3.53(1.6)
FRN003C1-4U** DCR4-2.2 0.59(15) 4.41(2.0)
FRN005C1-4U** DCR4-3.7 0.79(20) 5.73(2.6)
DCR2-0.2 0.2(5) 1.76(0.8)FRNF12C1-7U
Applicable inverter type
Three-phase 460V series
3.7
(94)
4.33
(110)
0.2
(5.2)
x
0.31
(8)
0.24
(6)
x
0.35
(9)
2.6
(66)
3.39
(86)
2.2
(56)
2.8
(71)
2.83
(72)
3.15
(80)
3.54
(90)
3.
94
(100)
0.79(20)
0.
24
(6)
x
0.35
(9)
3.7
(94)
4.33
(110)
0.79(20)
0.2
(5.2)
x
0.31
(8)
2.83
(72)
3.15
(80)
3.54
(90)
3.94
(100)
Reactor
type
Dimensions
Terminal
screw
Mass
[lbs(kg)]
2.6
(66)
3.39
(86)
2.2
(56)
2.8
(71)
Power
supply
voltage
Nominal
applied
motor
[HP]
Inverter type
Magnetic contactor (MC) Recommended wire size [mm
2
]
With DCR
Without reactor
With DCR
Without reactor
With DCR
Without reactor
Input circuit
Output
circuit
Input circuit [L1/R, L2/S, L3/T]
Output
circuit
[U, V, W]
DCR
circuit
[P1, P(+)]
DB
circuit
[P(+), DB, N(-)]
MCCB or GFCI
Rated current [A]
Three-
phase
230V
Three-
phase
460V
Single-
phase
230V
Single-
phase
115V
27
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Other manuals for Fuji Electric frenic mini series

Related product manuals