EasyManua.ls Logo

Fuji Electric frenic mini series - Standard Specifications

Fuji Electric frenic mini series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standard Specifications
Type (FRN

C1S-
U)
Applicable motor rating *1) 1/81/41/212351/21235
Enclosure (IEC 60529)
Cooling method
Weight / Mass
IP20, UL open type *11)
Natural cooling
1.3(0.6) 1.3(0.6) 1.3(0.6) 1.5(0.7) 3.7(1.7) 3.7(1.7) 5.1(2.3) 2.4(1.1) 2.6(1.2) 3.7(1.7) 3.7(1.7) 5.1(2.3)
Fan cooling Natural cooling Fan cooling
Rated capacity *2) 0.31 0.59 1.1 1.9 3.1 4.3 6.7 1.1 1.9 2.9 4.3 7.1
Rated current *4) A
%
%
lbs.(kg)
A
HP
kVA
kVA
V
A
%
%
lbs.(kg)
HP
kVA
kVA
V
0.8
(0.7)
1.5
(1.4)
3.0
(2.5)
5.0
(4.2)
8.0
(7.0)
11.0
(10.0)
17.0
(16.5)
1.5 2.5 3.7 5.5 9.0
Rated voltage *3)
Overload capability 150% of rated current for 1min, 200% of rated current for 0.5s
Rated frequency
Phases, voltage, frequency Three-phase, 200 to 240V, 50/60Hz Three-phase, 380 to 480V, 50/60Hz
Voltage/frequency variations
Required power supply capacity *7) 0.2 0.3 0.6 1.1 2.0 2.9 4.9 0.6 1.1 2.0 2.9 4.9
Torque *8) 150 100 50 30 100 50 30
Torque *9)
DC injection braking
-
150 150
Starting frequency: 0.0 to 60.0Hz Braking time: 0.0 to 30.0s Braking level: 0 to 100% of rated current
Voltage: +10 to -15% (Voltage unbalance *10) : 2% or less) Frequency: +5 to -5%
Rated current *6)
Momentary voltage dip capability *5)
(with DCR)
(without DCR)
0.57
1.1
0.93
1.8
1.6
3.1
3.0
5.3
5.7
9.5
8.3
13.2
14.0
22.2
0.85
1.7
1.6
3.1
3.0
5.9
4.4
8.2
7.3
13.0
50, 60Hz
Three-phase, 200V/50Hz, 200, 220, 230V/60Hz
Three-phase, 380, 400, 415V/50Hz, 380, 400, 440, 460V/60Hz
Input power source
FRNF12
C1S-2U
FRNF25
C1S-2U
FRNF50
C1S-2U
FRN001
C1S-2U
FRN002
C1S-2U
FRN003
C1S-2U
FRN005
C1S-2U
FRNF50
C1S-4U
FRN001
C1S-4U
FRN002
C1S-4U
FRN003
C1S-4U
FRN005
C1S-4U
Three-phase 230V
Item Specifications
Three-phase 460V
Output ratingsInput ratingsBraking
Type (FRN

C1S-
U)
Applicable motor rating *1) 1/8 1/4 1/2 1 2 3
Enclosure (IEC 60529)
Cooling method
Weight / Mass
IP20, UL open type *11) IP20
Natural cooling
1.3(0.6) 1.3(0.6) 1.3(0.6) 1.8(0.8) 3.7(1.7) 5.1(2.3)
Fan cooling
Rated capacity *2) 0.31 0.59 1.1 1.9 3.1 4.3
Rated current *4)
0.8
(0.7)
1.5
(1.4)
3.0
(2.5)
5.0
(4.2)
8.0
(7.0)
11.0
(10.0)
Rated voltage *3)
Overload capability 150% of rated current for 1 min, 200% of rated current for 0.5s
Rated frequency
Phases, voltage, frequency Single-phase, 200 to 240V, 50/60Hz Single-phase, 100 to 120V, 50/60Hz
Voltage/frequency variations
Required power supply capacity *7) 0.3 0.4 0.7 1.3 2.4 3.5
Torque *8) 150 100 3050
Torque *9)
DC injection braking
-
150
Starting frequency: 0.0 to 60.0Hz Braking time: 0.0 to 30.0s Braking level: 0 to 100% of rated current
Voltage: +10 to -10% Frequency: +5 to -5%
Momentary voltage dip capability *5)
Rated current *6) A
(with DCR)
(without DCR)
1.1
1.8
2.0
3.3
3.5
5.4
6.4
9.7
11.6
16.4
17.5
24.8
50, 60Hz
Three-phase, 200V/50Hz, 200, 220, 230V/60Hz
Input power source
FRNF12
C1S-7U
FRNF25
C1S-7U
FRNF50
C1S-7U
FRN001
C1S-7U
FRN002
C1S-7U
FRN003
C1S-7U
Single-phase 230V Single-phase 115V
*12)
Item Specifications
Output ratingsInput ratingsBraking
*1) Standard 4-pole motor
*2) Rated capacity is calculated by regarding the output rated voltage as 220V for three-phase 230V
and single-phase 230V series, and as 440V for three-phase 460V series.
*3) Output voltage cannot exceed the power supply voltage.
*4) Use the inverter at the current given in ( ) or below when the carrier frequency setting is higher
than 4kHz ( : to ) or the ambient temperature is 40°C (104°F) or higher.
*5) Tested under the standard load condition (85% load for nominal applied motor).
*6) Calculated under Fuji-specified conditions.
*7) Obtained when a DC REACTOR (option) is used.
*8) Average braking torque obtained with AVR control OFF (Varies with the efficiency of the motor.)
*9) Average braking torque obtained by use of external braking resistor (standard type available as option)
Three-phase series
Single-phase series
Standard specifications
When the input voltage is 165V or more, the inverter continues operation. If it
drops below 165V, the inverter operates for 15ms.
When the input voltage is 300V or more, the inverter
continues operation. If it drops below 300V, the inverter
operates for 15ms.
1/8 1/4 1/2 1
1.3(0.6) 1.3(0.6) 1.5(0.7) 2.6(1.2)
Natural cooling
0.26 0.53 0.95 1.6
0.7 1.4 2.5 4.2
0.3 0.5 0.7 1.3
150 100
150
-
2.2
3.6
3.8
5.9
6.4
9.5
12.0
16.1
FRNF12
C1S-6U
FRNF25
C1S-6U
FRNF50
C1S-6U
FRN001
C1S-6U
When the input voltage is 165V or more, the inverter continues operation. If it
drops below 165V, the inverter operates for 15ms.
When the input voltage is 85V or more, the inverter
continues operation. If it drops below 85V, the inverter
operates for 15ms.
8