3. WIRING
Follow the procedure below (In the following description, the inverter has already been installed).
3.1 Removing the terminal cover and the main circuit terminal block cover
(1) For inverters with a capacity of less than 5.5 kW
To remove the terminal cover, put your finger in the dimple of the terminal cover (labeled "PULL"), and then pull it up toward you.
To remove the main circuit terminal block cover, hold its right and left ends with your fingers and slide it toward you.
Figure 3.1 Removing the Covers (For Inverters with a Capacity of Less Than 5.5 kW)
(2) For inverters with a capacity of 5.5 and 7.5 kW
To remove the terminal cover, first loosen the terminal cover fixing screw, put your finger in the dimple of the terminal cover (labeled
"PULL"), and then pull it up towards you.
To remove the main circuit terminal block cover, put your thumbs on the handles of the main circuit terminal block cover, and push it
up while supporting it with your fingers (Refer to Figure 3.2).
Figure 3.2 Removing the Covers (For Inverters with a Capacity of 5.5 and 7.5 kW)