2 - 82
1747-KE
Set up the parameters for 1747-KE, using the software specifically designed for this purpose.
DF1 Port Setup Menu
Baudrate : 19200
Bits Per Character : 8
Parity : Even
Stop Bits : 1
DF1 Full-Duplex Setup Parameters
Duplicate Packet Detection : Enabled
Checksum : BCC
Constant Carrier Detect : Disabled
Message Timeout : 400
Hardware Handshaking : Disabled
Embedded Response Detect : Auto Detect
ACK Timeout( 5ms) : 90
ENQuiry Retries : 3
NAK Received Retries : 3
Wiring
The following is a diagram to show the wiring of the cable which connects POD to PLC.
RS-232C
Wiring Diagram 1
D-sub 25pin(Male: )
FG
SD
RD
RS
CS
1
2
3
4
5
DCD
RXD
PLC
D-sub 9pin(Female: )
TXD
DTR
1
2
3
4
5
COM
DSR 6
7
8
RTS
CTS
SG 7
POD (CN1)
*
Use twist shielded cables.