2 - 103
Shinko PLC
38
Available PLC
Communication Setting
The recommended communication parameter setting of both PLC and POD is as follows:
Available Memory
Only D register is available for this PLC model.
No other devices can be used although they are available to be set in theUG00S-
CW.
Set the memory to the extent of the memory range of each PLC model.
Use TYPE number to assign indirect memory for macro programs.
19200bps
Even
7 (ASCII)
Baud Rate
Parity
Transmission
Code
Data Length
Stop Bit 1
Sum Check
Item Setting of PLC
19200bps
Even
7
1
Comm. Parameter of POD
Provided (fixed)
RS-232C [Wiring Diagram 1]
PLC
SELMART-100 or later series
Select PLC Type
SELMART
Version O1M2-UCI-6x
Wiring Diagram
Link Unit
38 Shinko PLC
Memory TYPE Remarks
D(data register) 0