2 - 67
24 TOYOPUC PLC
TOYOPUC PLC
Available PLC
Communication Setting
The recommended communication parameter setting of both PLC and POD is as follows:
Set the [Trans. Mode] for [Detail] in the [Comm. Parameter].
· PC3J : Select [Single Data Area] or [Split Data Area].
· L2/PC2 series : Select [Single Data Area].
Switch Setting
Baud rate: 19200bps
24
Trans. Mode Contents
Single Data Area Data area is common.
Split Data Area Divide each PLC device into a program file.
PLC
CMP-LINK
RS-422 [Wiring Diagram 1]
Select PLC Type
TOYOPUC
L2/PC2 Series
PC3J
Wiring DiagramLink Unit
19200bps
Even
0
Baud Rate
Parity
Transmission
Code
Data Length
Stop Bit 2
Port
Item Setting of PLC
19200bps
Even
2
0
77
Comm. Parameter of POD
SW1
Switch
SW2
SW3
0
0
1
Setting Contents
Station address (lower half)
Station address (upper half)
Baud rate
1 : 19200 2 : 9600 3 : 4800
4 : 2400 5 : 1200 6 : 600
SET2
Switch
SET3
Provided
Provided
Short bar
Contents
Data bit 7
Stop bit 2