2 - 24
8 MITSUBISHI PLC 2
PLC
D-sub 25pin(Male: )
D-sub 25pin(Male: )
FG
SG
1
7
12
13
14
17
2
7
15
SG
16
4
17
5
18
20
21
3
18
19
24
25
POD (CN1)
+
SD
-
SD
+
RTS
-
RTS
-
CTS
+
CTS
+
RD
-
RD
+
RxD
+
TxD
+
DSR
+
DTR
-
RxD
-
TxD
-
DSR
-
DTR
*
Use twist shielded cables.
Wiring
The following is a diagram to show the wiring of the cable which connects POD to PLC.
(connection of the UG200C-M)
RS-422
Wiring Diagram 1
According to our noise tests, the attachment of a ferrite core improves
noise voltage by 650~900V and aids in preventing communication errors.
Note
In case of direct connection with the CPU port of A/QnA series, be sure to attach the
ferrite core to the cable between POD and the CPU port of A/QnA series for noise.
A Ferrite core is sold as an optional accessory.
A noise filter(ferrite core) is sold as an optional accessory. When you buy it, specify
“ZCAT032-0930” as the model name.
In consideration of such noise problems, it is recommended that the standard type link
unit be used in such a case when the cable length of more than 15m is required.