EasyManua.ls Logo

Fujitsu AOYG09LMCE - No Cooling; No Heating

Fujitsu AOYG09LMCE
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. Additional charge calculation
7-1. Models:AOYG07LMCE and AOYG09LMCE
Refrigerant type R410A
Refrigerant amount g 700
¢ Refrigerant charge
Total pipe length m 15 or less 20 (Max.)
20 g/m
Additional charge g 0 100
7-2. Model:AOYG12LMCE
Refrigerant type R410A
Refrigerant amount g 850
¢ Refrigerant charge
Total pipe length m 15 or less 20 (Max.)
20 g/m
Additional charge g 0 100
7-3. Model:AOYG14LMCE
Refrigerant type R410A
Refrigerant amount g 1,050
¢ Refrigerant charge
Total pipe length m 15 or less 20 (Max.)
20 g/m
Additional charge g 0 100
- 45 -
OUTDOOR UNIT
AOYG07-14LMCE

Table of Contents

Other manuals for Fujitsu AOYG09LMCE

Related product manuals